THIES CLIMA ULTRASONIC ANEMOMETER 2D 4.3820.01.310

THIES CLIMA ULTRASONIC ANEMOMETER 2D 4.3820.01.310
To get more information about products, please log in or request the product via the button below | Register here...
ULTRASONIC ANEMOMETER 2D
 485/422,HD;96N81,3 X 4-20 mA

Ready for shipment 17 Workdays

  • WS3602925
ULTRASONIC ANEMOMETER 2D  485/422,HD;96N81,3 X 4-20 mA  THE ULTRASONIC ANEMOMETER... more
Product information "THIES CLIMA ULTRASONIC ANEMOMETER 2D 4.3820.01.310"
ULTRASONIC ANEMOMETER 2D
 485/422,HD;96N81,3 X 4-20 mA
 THE ULTRASONIC ANEMOMETER SERVES FOR THE
 ACQUISITION OF THE HORIZONTAL COMPONENTS
 OF WIND VELOCITY AND WIND DIRECTION.
 AND THE ACOUSTICALL VIRTUAL TEMPERATURE.
 THE MEASURED VALUES ARE DELIVERED
 IN DIGITAL AND ANALOG FORM.
 THE ACOUSTIC MEASURING PRINCIPLE
 ALLOWS THE HIGH PRECISION
 MEASUREMENT OF RUNNING VARIABLE
 DIMENSIONS AND AN INERTIA-FREE
 PEAK VALUE ACQUISITION.
 BY THE CONTACTLESS MEASURING
 METHOD THE INSTRUMENT WORKS
 WEAR-FREE.
 THE INTEGRATED HEATING ALLOWES
 A DISTURBANCE-FREE WINTER OPERATION.
 TECHNICAL DATA:
 WIND VELOCITY
 MEASURING RANGE: 0...85 m/s
 RESOLUTION: 0,1 m/s
 ACCURACY: +/- 0,1 m/s, (0...5 m/s)
 +/- 2,0 % (> 5 m/s)
 WIND DIRECTION
 MEASURING RANGE: 0...360 DEG.
 RESOLUTION: 1 DEG.
 ACCURACY: +/- 1,0 DEG.
 VIRTUAL TEMPERATURE:
 MEAS. RANGE: -50...+70 DEG. C
 RESOLUTION: 0,1 K
 ACCURACY: +/- 0,5 K
 DATA OUTPUT DIGITAL:
 INTERFACE: RS 485/ RS 422
 BAUDRATE: 1200...921600
 OUTPUT: INSTANTANEOUS VALUES
 WIND-SPEED, -DIRECTION
 VIRTUAL TEMPERATURE
 GLIDING MEAN VALUE 0,5sec...100min
 (DIRECTIONAL VECTORIAL)
 STANDARD DEVIATION
 PREDEFINED AND USER DEFINED TELEGRAMS
 OUTPUT RATE: 100 PER SECOND
 DATA OUTPUT ANALOG (IF APPLICABLE):
 ELECTR. OUTPUT: 0/2...10 V OR 0/4...20 mA
 PARAMETER: WIND-SPEED,-DIRECTION
 VIRTUAL TEMPERATURE
 INSTANTANEOUS VALUES OR GLIDING  MEAN VALUES
 MAX LOAD CURRENT OUTPUT: 400OHM
 MIN LOAD VOLTAGE OUTPUT: 4000OHM
 REFRESH RATE: 1...100Hz
 RESOLUTION: 16 BIT
 DATA INPUT ANALOG (IF APPLICABLE):
 NUMBER: 3 X 0...10V
 RESOLUTION: 16BIT
 SAMPLING RATE: 0,1...100HZ
 ACCURACY: +/-01,% @ -50...70°C
 DATA OUTPUT: VIA SERIAL TELEGRAM
 GENERAL:
 INTERNAL MEAS.RATE: 400 Hz, AT 20 DEG. C
 BUS OPERATION UP TO 99 UNITS
OPERATING VOLTAGE:
 WITHOUT HEATING: 8..42V DC / 12-30VAC TYP.1,5VA
 WITH HEATING: 24 V AC/DC ,TYP. 80 VA MAX 90VA
 TEMPERATURE RANGE: -50...+70 DEG
 MOUNTING ON TUBE:1,5"/48,3mm
 WEIGHT: 2,5kg
 HOUSING: STAINLESS STEEL V4A
 EMV:55022:1998, EN55024:1998,
 EN61326:1997, A3:2003
 CONNECTION: 8PIN PLUG IN POLE
 PROTECTION CLASS: IP 67
Related links to "THIES CLIMA ULTRASONIC ANEMOMETER 2D 4.3820.01.310"
Read, write and discuss reviews... more
Customer evaluation for "THIES CLIMA ULTRASONIC ANEMOMETER 2D 4.3820.01.310"
Write an evaluation
Evaluations will be activated after verification.
Please enter these characters in the following text field.

The fields marked with * are required.

Last viewed wind turbine spare parts and repair material