Products from 3M Deutschland GmbH
![3M Deutschland GmbH](https://www.windsourcing.com/media/image/17/40/91/3M_800x800.jpg)
3M Deutschland GmbH has been a supply partner of WINDSOURCING.COM for rotor blade repair products and other wind turbine-related products for many years:
- 3M erosion protection for rotor blades
- 3M™ Wind Protection Tapes
- W2600 3M™ Wind Protection Tape Edge Sealer
- W9900 3M™ Wind Tape and Residue Remover (TARR) W9900
- W9910 3M™ Wind Tape Adhesion Promoter W9910
- 3M™ Wind Blade Protection Coatings and Accessories
- 3M™ Wind Blade Protection Coating W4600 and W4601
- 3M™ Wind Structural Adhesives and Accessories
- 3M Acryclic Foam Tapes and 3M™ Premium Electrical Tapes
No results were found for the filter!
3M™ 91-AHA 25-N is a heatshrink low voltage inline joint kit for crimp connectors, designed for 4-core shielded or armoured, low voltage polymeric insulated energy cables up to 0.6/1 kV according to HD603 and IEC 60502-1. Shrink ratio is up to 4.5:1, min. shrink temperature is 135°C, operating temperature is -55°C to +130°C. Cable cross section range is 4x185-4x240 mm². RoHS compliant, halogen free. Good electrical insulation, moisture, mechanical and chemical resistance.
3M™ 91-AHMC 6/5 Heatshrink Kit is a low voltage inline joint kit. It includes crimp connectors designed for 5-core energy cables. The kit has a shrink ratio of up to 4.5:1, a minimum shrink temperature of 135 °C and operating temperatures between -55 °C to +130 °C.
3M™ 91-AHMC 6 Heatshrink Kit is a low voltage inline joint kit. It includes crimp connectors designed for 3-core and 4-core energy cables. The kit has a shrink ratio of up to 4.5:1, a minimum shrink temperature of 135 °C and operating temperatures between -55 °C to +130 °C.
91-AHSC-16/5 is a heatshrink low voltage inline joint kit including screw connectors, designed for 5-core non shielded, non armoured, low voltage polymeric insulated energy cables up to 0,6/1 kV according to HD603 and IEC 60502-1. Shrink ratio is up to 4,5:1, min. shrink temperature is 135°C, operating temperature is -55°C to +130°C. Cable cross section range is 5x6-5x16 mm². RoHS compliant, flame retardant - self extinguishing. Good electrical insulation, moisture, mechanical and chemical resistance
91-AHSC-185 is a heatshrink low voltage inline joint kit including screw connectors, designed for 3-core and 4-core non shielded, non armoured, low voltage polymeric insulated energy cables up to 0,6/1 kV according to HD603 and IEC 60502-1. Shrink ratio is up to 4,5:1, min. shrink temperature is 135°C, operating temperature is -55°C to +130°C. Cable cross section range is 3x120-4x185 mm². RoHS compliant, flame retardant - self extinguishing. Good electrical insulation, moisture, mechanical and chemical resistance
91-AHSC-35/5N is a heatshrink low voltage inline joint kit including screw connectors, designed for 5-core non shielded, non armoured, low voltage polymeric insulated energy cables up to 0,6/1 kV according to HD603 and IEC 60502-1. Shrink ratio is up to 4,5:1, min. shrink temperature is 135°C, operating temperature is -55°C to +130°C. Cable cross section range is 5x16-5x35 mm². RoHS compliant, flame retardant - self extinguishing. Good electrical insulation, moisture, mechanical and chemical resistance
91-AHSC-35 is a heatshrink low voltage inline joint kit including screw connectors, designed for 3-core and 4-core non shielded, non armoured, low voltage polymeric insulated energy cables up to 0,6/1 kV according to HD603 and IEC 60502-1. Shrink ratio is up to 4,5:1, min. shrink temperature is 135°C, operating temperature is -55°C to +130°C. Cable cross section range is 3x6-4x35 mm². RoHS compliant, flame retardant - self extinguishing. Good electrical insulation, moisture, mechanical and chemical resistance
91-AHSC-95 is a heatshrink low voltage inline joint kit including screw connectors, designed for 3-core and 4-core non shielded, non armoured, low voltage polymeric insulated energy cables up to 0,6/1 kV according to HD603 and IEC 60502-1. Shrink ratio is up to 4,5:1, min. shrink temperature is 135°C, operating temperature is -55°C to +130°C. Cable cross section range is 3x50-4x95 mm². RoHS compliant, flame retardant - self extinguishing. Good electrical insulation, moisture, mechanical and chemical resistance
Last viewed wind turbine spare parts and repair material